- Density conforming to ASTM D 1622M
- Compressive strength conforming to ASTM D 1621
- Tensile Strength conforming to ASTM D 1623
- Water absorption conforming to ASTM D 2842
- Moisture Vapor Transmission conforming to ASTM E 96
- Dimensional Stability conforming to ASTM D 2126
- Closed Cell Content conforming to ASTM D 2856
- Surface Burning Characteristics conforming to ASTM E 84
- Fire Tests of Roof Covering conforming to ASTM E 108, Class A
Conforms to:
- Miami-Dade: NOA No. 01-0521.02
- SBCCI Standard for Hurricane Resistant Residential Construction, SBCCI Evaluation Report 9822B
- ICBO for One and Two Family Dwellings, ICBO ER-5595
- Florida Building Code, Product Approval #FL830
- Texas Department of Insurance Evaluation, Product Evaluation RC-22
Tile Installation: PolyPro AH160 Two-component Polyurethane Roof Tile Adhesive:
Slopes up to and including 6:12: Eave course may be fastened for alignment purposes only (not required)
Slopes above 6:12 and including 7:12: Fasten eave course and every third tile in every fifth course with one fastener
Slopes above 6:12 and including 7:12: Fasten eave course and every third tile in every fifth course with one fastener
Slopes Above 7:12:
Two piece barrel tile with slopes up to and including 6:12: Eave course may be fastened for alignment purposes only (not required)
Two piece barrel tile with slopes above 6:12 up to and including 7:12: Fasten pan tiles of the eave course and every pan tile in every fifth course with one fastener
Two piece barrel tile with slopes above 7:12: Fasten every cover and pan tile with one fastener
Two piece barrel tile with slopes above 7:12: The use of treated wood stringers under cover tile is acceptable
- Density conforming to ASTM D 1622
- Compressive strength conforming to ASTM D 1621
- Tensile Strength conforming to ASTM D 1623
- Water absorption conforming to ASTM D 2842
- Moisture Vapor Transmission conforming to ASTM E 96
- Dimensional Stability conforming to ASTM D 2126
- Closed Cell Content conforming to ASTM D 2856
- Surface Burning Characteristics conforming to ASTM E 84
- Fire Tests of Roof Covering conforming to ASTM E 108, Class A
Conforms to:
- Miami-Dade:Conforming to ASTM D 4586, Type II, non-asbestos, non-running type
- Florida Building Code, Product Approval #FL4180
Tile Installation - Polyset ONE one-component Polyurethane Roof Tile Adhesive:
Slopes up to and including 6:12: Eave course may be fastened for alignment purposes only (not required)
Slopes Above 7:12:
Two piece barrel tile with slopes up to and including 6:12: Eave course may be fastened for alignment purposes only (not required)
Two piece barrel tile with slopes above 6:12 up to and including 7:12: Fasten pan tiles of the eave course and every pan tile in every fifth course with one fastener
Two piece barrel tile with slopes above 7:12: Fasten every cover and pan tile with one fastener
Two piece barrel tile with slopes above 7:12: The use of treated wood stringers under cover tile is acceptable
Two-component polyurethane foam with the following properties:
- Density conforming to ASTM D 1622
- Compressive strength conforming to ASTM D 1621
- Tensile Strength conforming to ASTM D 1623
- Water absorption conforming to ASTM D 2842
- Moisture Vapor Transmission conforming to ASTM E 96
- Dimensional Stability conforming to ASTM D 2126
- Closed Cell Content conforming to ASTM D 2856
- Surface Burning Characteristics conforming to ASTM E 84
- Fire Tests of Roof Covering conforming to ASTM E 108, Class A
- Conforms to: Florida Building Code - TAS 100 "Test Procedure for Wind and Wind Driven Resistance of Discontinuous Roof Systems".
- Conforming to ASTM D 4586, Type II, non-asbestos, non-running type
- Modified Bitumen mastic conforming to ASTM D 3019, Type II